FS1A Safety Controller
![FS1A FS1A](https://www.kyaeautomation.com/wp-content/uploads/FS1A.jpg)
No programming required
Configuration complete by turning on a logic switch.
Features & Benefits
- A safety circuit can be configured easily just by selecting a logic from pre-programmed logics.
- Mode selection, partial/entire stop can be achieved just by selecting a logic.
- One SafetyOne module can connect with various safety inputs such as emergency stop switches and light curtains.
- The status of safety I/Os and the SafetyOne errors can be monitored.
- IEC 61508 safety integrity level 3, ISO 13849-1 performance level e, and category 4 compliant.
Type
Name
Downloads
HR1S-AC Safety Relay Modules
![HR1S-AC HR1S-AC](https://www.kyaeautomation.com/wp-content/uploads/HR1S-AC.jpg)
Transistor output provided
Removable terminal block with fault diagnosis function.
Features & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
Type
Name
Downloads
HR1S-AF Safety Relay Modules
![HR1S-AF HR1S-AF](https://www.kyaeautomation.com/wp-content/uploads/HR1S-AF.jpg)
Removable terminal block with fault diagnosis function
Small and high function (welding detection of start switch).
Features & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
Type
Name
Downloads
HR1S-AK Safety Relay Modules
![HR1S-AK HR1S-AK](https://www.kyaeautomation.com/wp-content/uploads/HR1S-AK.jpg)
Four transistor outputs
Finger safe protection with fault diagnosis function.
Features & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Can be connected to light curtain.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
Type
Name
Downloads
HR1S-ATE Safety Relay Modules
![HR1S-ATE (1) HR1S-ATE (1)](https://www.kyaeautomation.com/wp-content/uploads/HR1S-ATE-1.jpg)
New compact safety relay modules
Size is reduced by 50% from conventional models, plug-in terminal structures enables simple wiring.
Features & Benefits
- EN ISO 13849-1 performance level e, safety category 4 compliant, and EN 62061 safety integrity level 3.
- Integrated and removable terminal styles available.
- Compact design: 45 mm in width.
- Time delay outputs: 3NO
- Auxiliary output enables power supply monitoring, inputs (2 channels), and a time delay output.
- Environmentally friendly, RoHs directive compliant.
- UL Listed, CSA certified, TÜV NORD approved.
Type
Name
Downloads
HR1S-DMB/DME Safety Relay Modules
![HR1S-DMB_DME HR1S-DMB_DME](https://www.kyaeautomation.com/wp-content/uploads/HR1S-DMB_DME.jpg)
Removable terminal block with IP67 degree of protection
Safety relay module for non-contact interlock switch.
Features & Benefits
- 1NO-1NC safety input type, such as magnetic coded safety switches
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED Indicator.
- Finger-safe protection
- 22.5 or 45mm wide, 35mm DIN rail mounting
- EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3
- UL listed, CSA certified, TÜV NORD approved
Type
Name
Downloads
HR2S-301P/HR2S-301N Safety Relay Modules
![30RA 30RA](https://www.kyaeautomation.com/wp-content/uploads/30RA.jpg)
Safety Category 4, PLe
Compact design and maintenance improvements for outstanding usability!
Features & Benefits
- Compliant with EN ISO 13849-1 Performance level (PL) e, Category 4.
- Compliant with categories 2 (type 2) and 4 (type 4) when used with a safety light curtain.
- Spring terminals enable easy wiring.
- The terminal cover does not close if the terminal is not fully inserted into the module.
- IP20 (terminal) / IP40 (housing)
Type
Name
Downloads
HR2S-322N-T075/T15/T30 Safety Relay Modules
![30RB 30RB](https://www.kyaeautomation.com/wp-content/uploads/30RB.jpg)
Simple wiring procedure with removable terminal block
Time delay output compliant to category 4.
Features & Benefits
- Compliant with EN ISO 13849-1 Performance level (PL) e, Category 4.
- Compliant with categories 2 (type 2) and 4 (type 4) when used with a safety light curtain.
- Spring terminals enable easy wiring.
- The terminal cover does not close if the terminal is not fully inserted into the module.
- IP20 (terminal) / IP40 (housing)